LD2050 DC CONTROLLER
FOR PIR & LUX SENSORS

  • DIMMING
  • 4 TIME DELAY SETTINGS
  • FADE-IN/FADE-OUT

LD2050 LUX and PIR controller

 

INSTALLATION INSTRUCTIONS & TROUBLESHOOTING

CONNECTING POWER
1. Slide off the terminal cover.
2. Connect power either by:
a) plugging in a 12/24VDC power adapter
OR
b) hardwire directly from a 12/24VDC LED driver to the screw terminals marked “INPUT”.
3. Connect the LED strip using the screw terminals marked “OUTPUT” (5A maximum load).

CONNECTING THE SENSORS 
Plug the PIR sensor into the LHS socket and the LUX sensor into the RHS socket.

DIMMING
If light is too bright, slide off the terminal cover and adjust the dial to suit the required light level.

TIMER SETTINGS
The two DIP switches set the time delay to turn off the light when there is no further triggering. Time settings are 15s, 30s, 1m, 2m.
If re-triggered prior to timing out the timer restarts from zero.
To set, slide off the connection cover and set the DIP switches as follows.

 

timer setting for LD2050


TROUBLESHOOTING

  • Is the polarity correct for input and output power?
  • Connect the LED light directly to the power supply and check if working and the correct polarity.
  • To test the controller, disconnect all sensors and place the supplied black jumper between the left pin and the centre pin of the LUX input and then using a screwdriver short the two LHS pins of the PIR sensor input. The light should now be on. Remove the jumper on the PIR input and the light will turn off when the timer times out.
  • To test the PIR sensor place the jumper on the two LHS pine of the LUX input and plug the PIR sensor into the PIR input and test with motion.
  • Contact Lightdream Technical Support by phone while on-site if you require additional assistance.

SPECIFICATIONS
Designed for 12/24V LED lighting
Voltage: 12/24VDC
Load current (max): 5A
Maximum load: 60W @ 12V, 120W @ 24V.
Sensor inputs: 2
Dimming: 0-100%
Timer: 15s, 30s, 1m, 2m