LD2083
REMOTE CONTROL DONGLE
dongle LD2083

PAIRING BLACK OR WHITE REMOTE BUTTONS

LD2000-P – simple on/off use
Can control one or two independent loads

1. On the LD2000-P controller push the 3 x RHS DIP SWITCHES up to “ON” for infinity.
2. Push up LHS DIP switch to “ON” to select two channels – LOAD A and LOAD B.
3. Connect first dongle to Sensor Input 1. Leave jumper on Sensor Input 2.
4. If required, connect 2nd dongle to Sensor Input 3. Leave jumper on Sensor Input 4.
5. Connect loads and power up controller.
6. Press each dongle button 8 times. Light will flash 7 times. This clears any previous codes.
7. Press the first dongle button twice. The indicator light will come on.
8. Immediately press the remote button. The indicator light will flash 3 times.
9. Now press the remote button to turn on, then press again to turn off.
10. Repeat steps 5-9 for the next dongle.

LD2000-P – time delay use
Can control one or two independent loads

1. On the LD2000-P controller select the time delay according to the table on the controller using the 3 x RHS DIP switches.
2. Push up LHS DIP switch to “ON” to select two channels – LOAD A and LOAD B.
3. Connect first dongle to Sensor Input 1. Leave jumper on Sensor Input 2.
4. If required, connect 2nd dongle to Sensor Input 3. Leave jumper on Sensor Input 4.
5. Connect loads and power up controller.
6. Press the first dongle button 8 times. Light will flash 7 times. This clears any previous codes.
7. Press the first dongle button once. The indicator light will come on.
8. Immediately press the remote button and the indicator light will flash 3 times.
9. Now press the remote button, the light will turn on and turn off at the end of the timer cycle.
10. Repeat steps 5-9 for the next dongle.